The US Food and Drug Administration (FDA) has released data on the observations it makes during inspections of biologics manufacturing facilities, indicating the most common issues faced by biologics companies.
In its most recent report, FY 2014 Inspectional Observation Summaries, FDA said it issued 146 Form 483s—forms indicating areas of noncompliance at a facility—to biologics companies in fiscal year 2014.
The number of 473s issued (146) is the lowest since FDA began keeping track of its 483 inspection data in 2006, and is the fifth consecutive year FDA has issued fewer 483s to biologics companies than the year prior.

FDA's inspections also noted common deficiencies by biologics manufacturers.
| Regulatory Citation | Short Description | Long Description | Frequency |
|---|---|---|---|
| 21 CFR 606.100(b) | Maintained and followed | Written standard operating procedures including all steps to be followed in the [collection] [processing] [compatibility testing] [storage] [distribution] of blood and blood components for [homologous transfusion] [autologous transfusion] [further manufacturing purposes] are not always [maintained] [followed] [maintained on the premises]. | 77 |
| 21 CFR 606.160(a)(1) | Concurrent documentation | Records are not concurrently maintained with the performance of each significant step in the [collection] [processing] [compatibility testing] [storage] [distribution] of each unit of blood and blood components so that all steps can be clearly traced. | 23 |
| 21 CFR 606.100(c) | Thorough investigations | Failure to [perform a thorough investigation] [make a record of the conclusions and follow-up] of [an unexplained discrepancy] [a failure of a lot or unit to meet any of its specifications]. | 21 |
| 21 CFR 606.171 | Biological product deviation report | Failure to submit a biological product deviation report [within 45 days from the date you acquired information suggesting that a reportable event occurred]. | 20 |
| 21 CFR 606.160(b) | Required records | Failure to maintain [donor] [processing] [storage and distribution] [compatibility testing] [quality control] [general] records. | 16 |
| 21 CFR 606.160(a)(1) | Person performing, test results, interpretation | Records fail to [identify the person performing the work] [include dates of the various entries] [show test results] [include interpretation of the results] [show the expiration date assigned to specific products] [be as detailed as necessary] so as to provide a complete history of the work performed. | 16 |
| 21 CFR 606.60(a) | Equipment observed, standardized, calibrated | Equipment used in the [collection] [processing] [compatibility testing] [storage and distribution] of blood and blood components is not [observed] [standardized] [calibrated] on a regularly scheduled basis as prescribed in the SOP Manual. | 11 |
| 21 CFR 606.65(e) | Following manufacturer's instructions | Failure to use supplies and reagents in a manner consistent with instructions provided by the manufacturer. | 10 |
| 21 CFR 606.100(b) | Written SOPs available for use by personnel | Failure to make available written procedures for use by personnel in the areas where the procedures are performed. | 8 |
| 21 CFR 606.100(c) | Record review prior to release | All records pertinent to a lot or unit were not reviewed before the release or distribution of a lot or unit of final product. | 8 |
| 21 CFR 606.160(a)(1) | Legibility and indelibility | Records are [illegible] [not indelible]. | 8 |
| 21 CFR 606.20(b) | Qualifications of responsible personnel | The personnel responsible for the [collection] [processing] [compatibility testing] [storage] [distribution] of blood or blood components are not adequate in [number] [educational background] [training and experience, including professional training as necessary] to assure competent performance of their assigned functions, and to ensure that the final product has the safety, purity, potency, identity and effectiveness it purports or is represented to possess. | 7 |
| 21 CFR 606.40(a)(1) | Provide space for examination | Failure to provide adequate space for [private] [accurate] examinations of individuals to determine their suitability as blood donors. | 7 |
| 21 CFR 606.60(b) | Equipment calibration frequency | Equipment used in the [collection][processing][compatibility testing][storage and distribution] of blood and blood components is not observed, standardized and calibrated with at least the frequency required. | 6 |
| 21 CFR 606.60(a) | Maintain and clean equipment | Failure to [maintain] [locate] equipment used in the [collection] [processing] [compatibility testing] [storage] [distribution] of blood and blood products [in a clean and orderly manner] [so as to facilitate cleaning and maintenance]. | 5 |
We have completed our migration to a new platform and are pleased to introduce the updated site.
What to expect: If you have an existing login, please RESET YOUR PASSWORD before signing in. After you log in for the first time, you will be prompted to confirm your profile preferences, which will be used to personalize content.
We encourage you to explore the new website and visit your updated My RAPS page. If you need assistance, please review our FAQ page.
We welcome your feedback. Please let us know how we can continue to improve your experience.